Uploaded image for project: 'PROFIBUS Slave'
  1. PROFIBUS Slave
  2. PSDPS-406

receiving invalid SetSlaveAdr profibus telegram (length < 4 bytes) leads to undefinded stack behaviour

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.5.2.0
    • Fix Version/s: V2.7.6.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profibus Slave (SPCPROFIBUSSL)

      Description

      If Master sends SetSlaveAdr telegram with to less data (4 bytes is required according to norm) inworst case entire memory is corrupted and firmware no longer working as expected

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  mark mark
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: