Uploaded image for project: 'PROFIBUS Slave'
  1. PROFIBUS Slave
  2. PSDPS-392

[netX51], [netX52]: Firmware does not start

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Critical
    • Resolution: Fixed
    • Affects Version/s: V2.7.1.0
    • Fix Version/s: V2.7.2.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profibus Slave (SPCPROFIBUSSL)

      Description

      The firmware "X0602000.nxf" can not be executed on a target netX51.

      LED RDY/RUN do not delivery a state.

      TAG List Editor delivery the error the common Header Version is not 3.0 (58783.12460) -> Inconsistent Offset / size entries in common header.

      The Firmware "X0702000.nxf" can not be executed on a target netX52. The 2nd Stage Bootloader can not start the Firmware. The netX52 target is hanging in the 2nd Stage Bootloader mode.