fClearFlag not set when data is cleared

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.2.0
    • Fix Version/s: V2.7.9.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profibus Slave (SPCPROFIBUSSL)

      Description

      When master switches to CLEAR mode process data are cleared in PROFIBUS_FSPMS_GET_OUTPUT_CNF_T, but fClearFlag remains off.

      flag should be set

      steps to reproduce :

      1.Configure master and slave for data exchange.(In master prj slave 'fail-save mode': - receives zero data and in salve cfg 'fail-safe' mode are marked as supported)

      2.Exchange process data between devices and final send maser in CLEAR mode

      3.Request output data in salve (PROFIBUS_FSPMS_CMD_GET_OUTPUT_REQ), check fClearFlag