Uploaded image for project: 'PROFIBUS Slave'
  1. PROFIBUS Slave
  2. PSDPS-341

Configuration failed when application controlled startup is selected in warmstart param

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.2.0
    • Fix Version/s: V2.6.5.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profibus Slave (SPCPROFIBUSSL)

      Description

      After sending PROFIBUS_APS_WARMSTART_PRM_REQ with controlled start of communication flag for the first time (after system reset) stack remains in unconfigured state. Additional channel init is needed to be set READY flag.

      Referring to API when pkt are send for the first time no additional channel init is required.

      no such behavior when automatic start of communication are selected

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  Georgi Georgi K [X] (Inactive)
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: