DNet attributes 6-9 do not show current state of switches set by RCX_SET_FW_PARAMETER_REQ

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.3.17.0
    • Fix Version/s: V2.3.19.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC DeviceNet Slave (SPCDEVICESL)

      Description

      Configure a slave with controlled release of communication.
      Using packet command RCX_SET_FW_PARAMETER_REQ set station address and baud rate.
      Set Bus state On.

      From master read DeviceNet object attributes 6-9 (3.1.x).

      Attributes 6 and 7 indicating a changed switch always show the same value, no matter if address and baudrate was changed or not.

      Attributes 8 and 9 indicating the value of the switches always show the same value, no matter which value is set on the switches.