Uploaded image for project: 'CANopen Master'
  1. CANopen Master
  2. PSCOM-154

[LFW] The COM-Bit is cleared when a Watchdog error is detected, but does NOT change RUN and Bus-on

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.10.1.0, V2.11.3.0, V2.12.1.0, V2.12.2.0, V2.12.3.0, V2.12.4.0
    • Fix Version/s: V2.12.5.0, V2.13.0.0
    • Component/s: Firmware
    • Labels:
      None
    • Sprint:
      CAN - 2014 KW 28-29
    • Account:
      SPC CanOpen Master (SPCCANOPENMA)

      Description

      In "H:\Manual netX Architecture\System\Watchdog\Watchdog behavior.doc" a common handling for watchdog error is defined.
      Currently following steps are not done:

      • clear Bus ON bit
      • clear running bit

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  et et
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: