Uploaded image for project: 'PROFINET IO Device V4 Product'
  1. PROFINET IO Device V4 Product
  2. PRODPNSV4-65

Feature: Add possbility to configure the supported amount of parallel ReadImplicit services and usable submodules

    Details

    • Type: User Story
    • Status: Closed
    • Priority: Minor
    • Resolution: Done
    • Affects Version/s: None
    • Fix Version/s: V4.4.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Due to new demands of Profinet specification (and certification) it shall be possible to configure the amount of parallel ReadImplicit services.

      Several aspects need to be taken in account

      • specification recommends 4 parallel services
      • netX52 has limited RAM resources
      • dependencies between several concurrent requirements requiring RAM
        • amount of IO ARs
        • amount of parallel ReadImplicit services
        • amount of possible usable submodules

      Thus it is required to be able to manipulate all these parameters. Some users may only use 1 IO AR but request 4 ReadImplicit, others may require only 8 submodules.