LED configuration and control for LFW (unused LEDs shall be set to off)

    Details

    • Type: User Story
    • Status: Closed
    • Priority: Minor
    • Resolution: Done
    • Affects Version/s: None
    • Fix Version/s: V3.10.0.0
    • Labels:
      None

      Description

      Customers following the netX51/52 DesignIn Guide face the problem that some LEDs glow. Customers expect the LEDs to be OFF.
      Hilscher hardware (NXHX52 or netRAPID) does not show the issue as additional resistors are used there.
      Unused LEDs need to be set to off by the firmware on startup so that no glow occurs.

      This shall be done by taglist. A taglist entry for each LED shall be created. The firmware shall use all four LEDs (as identified by taglist, including type (PIO/GPIO), number, ...) and disable unused LEDs.

      The LEDs in taglist shall be named "COM0_RED", "COM0_GREEN", "COM1_RED", "COM1_GREEN".