Uploaded image for project: 'netX Transport Toolkit'
  1. netX Transport Toolkit
  2. NXTTKIT-72

xChannelIOReadSendData() returns 0x800C0022

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V1.0.0.0, V1.0.1.0, V1.0.2.0, V1.0.3.0, V1.0.4.0, V1.0.5.0, V1.1.0.0, V1.2.0.0, V1.3.0.0
    • Fix Version/s: V1.4.0.0
    • Component/s: Toolkit Source
    • Labels:
      None
    • Account:
      SDO Transport, Diagnostic (SDOTRANSPO)

      Description

      xChannelIOReadSendData() returns 0x800C0022.

      Data length is not set in CHANNEL_IOREADSENDDATA_REQ_T structure in ChannelIOReadSendData(),TL_Marhsaller.c.

      The following line is missing:

      tReadSendREQ.tData.ulDataLen = ulDataLen;

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  SDoell Sebastian Döll
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: