UART interface: ACK packet gets lost and netX stucks inside endless loop

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.6.0, V1.6.2, V1.6.3
    • Fix Version/s: V1.8.0, V1.8.1
    • Component/s: None
    • Labels:
      None
    • Account:
      SCT CLIFlasher operational (CLIFLASHER)

      Description

      First CLI Flasher Call (to set up error situation)

      • Host sends a command to the netX
      • netX answers with ACK packet
      • netX sends answer for the command
      • Host sends ACK (ACK packet gets lost)

      Now the netX is still resending the answer packet and is waiting in an endless loop for the ACK packet.