Uploaded image for project: 'netX Transport RS232 Connector for Windows'
  1. netX Transport RS232 Connector for Windows
  2. NXTC232WIN-5

Data transfer stalls after some time (600.000 - 2.000.000 packets)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.0.3.0
    • Fix Version/s: V1.0.4.0
    • Component/s: General
    • Labels:
      None
    • Account:
      SDO Transport, Diagnostic (SDOTRANSPO)

      Description

      In the Send data handler, the overlapped events are not closed. This Handle leak may result in ReadFile to return ERROR_NOT_ENOUGH_QUOTA.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  MTrensch Michael Trensch
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: