Uploaded image for project: 'CIFX Toolkit'
  1. CIFX Toolkit
  2. NXDRVTKIT-67

Mailbox notification may cause illegal memory access due to missing hardware interface abstraction and endianness conversion

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.0.0.0, V1.0.1.0, V1.0.2.0, V1.0.3.0, V1.0.4.0, V1.1.0.0, V1.1.1.0, V1.1.2.0, V1.1.3.0, V1.1.4.0, V1.1.5.0
    • Fix Version/s: V1.2.0.0
    • Component/s: cifX/netX Toolkit
    • Labels:
      None
    • Account:
      SDO Driver (SDODRIVER)

      Description

      Reading package count in DSR handler lacks endianness conversion (LE_TO_HOST) and hardware abstraction macros (HWIF_READ).
      This may cause:

      • invalid memory accesses if device is connected via a custom hardware access interface
      • wrong endianess of the package counter of the mailbox notification on big endian machines

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  stephans stephans
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: