Description
The additional reset flags "Clear remanent" and "Verify Installation" not working when
triggered via the toolkit and a DPM connection is used (ulSystemControl variable not set).
Attachments
Issue Links
- blocks
-
NXDRVWIN-308 Reset options "Clear remanent" and "Verify installation" not working in cifXTest.exe
- Closed
- relates to
-
NXDRVWIN-311 Update cifXToolkit to V2.7.2.0
- Closed