Uploaded image for project: 'CIFX Driver for QNX'
  1. CIFX Driver for QNX
  2. NXDRVQNX-7

Unaligned DPM access may deliver invalid data

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V1.0.0.0
    • Fix Version/s: V1.0.1.0
    • Component/s: Driver
    • Labels:
      None
    • Account:
      SDO Driver (SDODRIVER)

      Description

      Unaligned data access to the netX DPM could deliver invalid (no) data. This was seen if by a Pericom PCIe to PCI bridge which translates "unaligned" memory accesses to "PCI Read-Line" commands. Such commands are spezified in the PCI 2.1/2.2 specification but not implemented in the netX 500/100 PCI core.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    stephans stephans
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: