      Description

      Configure NIC 52-REFO Profinet Device.
      During connect with Profinet controller, netIC reports ModuleDiffBlock with 1 module and 4 submodules.

      netX Config Tool uses DAP module and submodule identifiers of NIC 50-REFO (0x201, 0x200-0x203).
      In GSDML following identifiers are defined for NIC 52-REFO: 0x281, 0x280-0x283.
      ---------------------------------------------------------------------------------------------------------------------------------------------------------
      Configure NIC 52-RE Profinet Device.
      During connect with Profinet controller, netIC reports ModuleDiffBlock with 1 module and 4 submodules.

      netX Config Tool uses DAP module and submodule identifiers of NIC 50-REFO (0x201, 0x200-0x203).
      In GSDML following identifiers are defined for NIC 52-RE: 0x181, 0x180-0x183.