Details
-
Type: Bug
-
Status: Closed
-
Priority: Trivial
-
Resolution: Fixed
-
Affects Version/s: V1.4.9.0, V1.4.10.0, V1.4.11.0, V1.4.12.0, V1.4.12.1, V1.4.13.0, V1.4.14.0, V1.4.15.0, V1.4.16.0, V1.4.16.99, V1.4.17.0, V1.4.17.1
-
Fix Version/s: V1.4.18.0
-
Labels:None
-
Account:SDO Bootloader (SDOBOOTLOA)
Description
The Winbond flashes are kept in SQIROM mode by ROM loader. To leave this mode a reset command needs to be executed.
This is internally done inside the 2nd Stage Loader, but it is not passed in boot tokens to the firmware.
When using the 2nd Stage Loader the firmware does not need to send this command, so it's not a real error, but only a cosmetic issue.
Attachments
Issue Links
- relates to
-
NXBSL-107 Serial flash detection does not work, if flash is in wrong state at startup
- Closed