Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V2.0.0.9
-
Fix Version/s: V2.0.0.10
-
Component/s: FW Type EIS
-
Labels:None
-
Account:PROD netIC (PRODNETIC)
Description
Tested NIC 52-RE EIS V2.0.0.9.
NIC 52-RE EIS is configured by packet via Modbus RTU (netX Configuration Tool is not used). Device specific parameters are set to 0 to make the firmware use default values.
EIP_APS_SET_CONFIGURATION_PARAMETERS_REQ
Id : 0x0000 Cmd : 0x00003612
Len : 269 State : 0x00000000
ulParameterVersion: 1 ulSystemFlags: 0x00000000 ulWdgTime: 500 ulInputLen: 32 ul
OutputLen: 32 ulTcpFlag: 0x00000403 ulIpAddr: 192.168.10.2 ulNetMask: 255.255.25
5.0 ulGateway: 0.0.0.0 usVendId: 0 usProductType: 0 usProductCode: 0x0000 ulSeri
alNumber: 0 bMinorRev: 0 bMajorRev: 0 abDeviceName: "" ulInputAssInstance: 100 u
lInputAssFlags: 0x00000001 ulOutputAssInstance: 101 ulOutputAssFlags: 0x00000000
Other parameters are set to 0.
After configuration the Identity object is read by EtherNet/IP master.
Get Attribut All Class 1 (Identity) Instance 1:
1B01 - 1: Vendor Code (283 = Hilscher)
0C00 - 2: Product Type
0D01 - 3: Product Code (269 = NIC 50-RE)
01 01 - 4: Version
3000 - 5: Status
494E0000 - 6: Serial Number
0D4E49432035302D52452F454953 - 7: Product Name ("NIC 50-RE/EIS")
03 - 8: State
0000 - 9: Config Consistent
00
Expected:
1E01 - 3: Product Code (286 = NIC 52-RE)
0D4E49432035322D52452F454953 - 7: Product Name ("NIC 52-RE/EIS")