Firmwareupdate over Webserver is not working

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.0.2.0
    • Fix Version/s: V2.0.3.0
    • Component/s: netX90 EIS, netX90 PNS
    • Labels:
      None
    • Account:
      PROD IoT LFW (PRODIOTLFW)

      Description

      The firmware update request over the webserver administration site is denied with the error code 500 "internal error", because the webserver has no privilege to read out the group the user belongs to. The authentication manager has to be configured with 'AUTH_USRDB_CFGOPT_SUPPORT_GROUP_READ' enabled.