Configuring a Profinet IO Slave with Plugable Subslots not possible

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V1.0009.2.9157
    • Fix Version/s: V1.0009.3.1219, V1.0010.3.2551
    • Component/s: DTM
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When Configuring a Profinet IO Slave with plugable subslots it is not possible to add subslots to a module. The button "Add Submodule" stays grayed when the module is selected.

      When closing the Slave Dialog, the following error message is generated:

      XML Parse Error, Code: 0xC00CE011, URL: no url, Reason: Element cannot be empty according to the DTD/Schema. Source: 							<pn:ModuleList><pn:Module slotNumber="0" moduleIdentNumber="1" fdt:name="IWG Gateway" fdt:descriptor="IWG Gateway" moduleProperties="0"><pn:SubModuleList><pn:SubModule subSlotNumber="1" subModu (Line 25, Linepos 1952, Filepos 3999). String loaded: DTMParameter 
      Given parameter-string at OnParameterChanged() is not valid according to the schemas. GetParameter() will be called instead. Device: IWG_Gateway[IWG Gateway]<simtec-iwg1-dap> 
      XML Parse Error, Code: 0xC00CE011, URL: no url, Reason: Element cannot be empty according to the DTD/Schema. Source: 							<pn:ModuleList><pn:Module slotNumber="0" moduleIdentNumber="1" fdt:name="IWG Gateway" fdt:descriptor="IWG Gateway" moduleProperties="0"><pn:SubModuleList><pn:SubModule subSlotNumber="1" subModu (Line 25, Linepos 1952, Filepos 3999). String loaded: DTMParameter 
      LoadParameters schlug fehl mit dem Gerät: IWG_Gateway[IWG Gateway]<simtec-iwg1-dap> 

      Details from DTM:

      DTM:	PROFINET IO Generic Device DTM
      	Info:		--
      	Hersteller:	Hilscher GmbH
      	Version:		V1.0009.2.2023
      	Datum:		2011-02-02
       
       Gerät:	IWG Gateway
      	Info:		IWG Gateway [0x00000001] [IDD_1] [GSDML-V2.2-SIMTEC-IWG-20140123.xml]
      	Hersteller:	SIMTEC Elektronik GmbH
      	Version:		--
      	Datum:		-- 

      A short test with TIA Portal showed no problems with the GSDML file. Submodules can be add as expected.