Handling of GSDML Keyword "ParameterizationDisallowed" is not correct

    Details

    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      The actual implementation of the keyword "ParameterizationDisallowed" is incorrect. Port- and Interface-Submodules are handled as "SharedDevices" and are not part of the DTMParameter XML. This is not correct!

      IRT controller DTM is using the Interface- & Port-Submodules fur Topology engineering and it is mandatory to get these kind of submodules!

      Solution: Controller DTM DTM is responsible to parse the "ParameterizationDisallowed" keyword, and handle the configuration/parameterization packets of these Submodules.