Details
- 
    Type:
Bug
 - 
    Status: Closed
 - 
    Priority:
Major
 - 
    Resolution: Fixed
 - 
    Affects Version/s: V1.1000.4.1875
 - 
    Fix Version/s: V1.1000.4.3144, V1.1100.4.3695
 - 
    Component/s: DTM
 - 
    Labels:None
 
Description
NT151 PN IO Device - SIII Master (as well as all other combinations with SIII Master) - configuration download fails. Caused by error in download from SIII Master DTM.
1/ Drop NT151-XX-XX to the main bus line
2/ Port X2 -> PROFINET IO Device; port X3 -> SERCOS III Master
3/ Drop CIFX_RE_S3S_FIXCFG_1000_CIFX_RE_S3S_FIXCFG to SIII Master's bus line
4/ Assign the NT151 DTM to the NT151 device
5/ Do configuration download:
Result: download to Ch1 (SIII Master) fails with error "Download failed (General error during download) -> Device: netTAP[NT 151-RE-RE]<>(#1)".
6/ Without disconnecting the DTM - do 2 more download attempts - the same error again.
7/ Do one more attempt - now the download passes without an error!
OS: Windows 8.1
SYCON.net 1.500 Build 160107
SYCON.net 1.400 Build 160323
SYCON.net 1.500 Build 160504
SYCON.net V1.400 (Build 160607) with the attached firmware (PNS-S3M).
Note: The situation is also observed using SIII Master DTM and assigning it to Ch1 of NT151 device but happens sometimes and rarely.