Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: V1.1100.6.9871, V2.0000.9.1535
-
Component/s: DTM
-
Labels:None
-
Epic Link:
Description
First issue
1. Drug and drop BRIN DTM and it shows correct name netTAP[NT 151-RE-RE/ECS/EIS-BRIN]
2. Save as it is and Close SYCON.net
3. Open saved project file and it still shows correct netTAP[NT 151-RE-RE/ECS/EIS-BRIN]
4. Right Click and the name is changed to netTAP[NT 151-RE-RE/ECS/EIS]
Automatic signal mapping cannot be done correctly.
Status is automatically mapped but other signals are not mapped.
Second issue
- Product codes are opposite
NT 151-RE-RE/ECS/EIS-BRIN: Current: 0x32020F01 --> Please correct to 0x32021001
NT 151-RE-RE/ECS/PNS-BRIN: Current: 0x32021001 --> Please correct to 0x32020F01
Third issue
200 bytes can not be mapped in ECS/PNS because of status bytes - increase the max possible size so that actual 200 bytes can be mapped.
Attachments
Issue Links
- relates to
-
DTMV1NETSL-574 NT 151 -BRIN devices - incorrect product code in ECS
- Resolved
-
DTMV1NETGW-1079 Add NT 151-ECS/EIS-BRIN and NT 151-ECS/PNS-BRIN devices with custom mapping.
- Closed