Details

    • Type: Bug
    • Status: Resolved
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.1100.6.644
    • Fix Version/s: V1.1100.6.2784, V2.0000.9.1535
    • Component/s: DTM
    • Labels:
      None

      Description

      Bug Description from Tester:

      I&M0 structure reported from NT151 RE-RE device to PROFINET IO Controller (Simatic Step7) visualizes not expected Order ID value - 1724.122. Currently, the NT151 RE-RE security memory information has 1722122 value preset for the same parameter (visualized on the device label, also).

       

      Steps to reproduce:
      1. Open SYCON.net
      2. Place NT151-RE-RE/PNS/OMB DTM.
      3. Assign the netTAP DTM to the hardware.
      4. Perform a standard firmware download
      5. Download to NT151 a configuration with default DTM parameters and ensure that cyclic communication with partnering devices is successfully started.
      6. Request I&M0 information via the PROFINET network.
      7. Compare reported in I&M0 structure OrderId value to that from device label.

       

      Expected result:
      Both values are equal.

       

      Actual result:
      OrderID = 1724.122

      DeviceNumber = 1722122

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  FFaehrmann Frank Fährmann
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: