Uploaded image for project: 'netGATEWAY DTM'
  1. netGATEWAY DTM
  2. DTMV1NETGW-1028

NT151 Coupler : Unable to use maximum bytes in coupler variables.

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.1100.5.6661, V2.0000.9.1535
    • Component/s: DTM
    • Labels:
      None
    • Account:
      PROD netGATEWAY (PRODNETGATEWAY)

      Description

      Steps to reproduce:

      1. Open the attached project.

      2. Check the PROFINET IO sizes - its 1430/1024 and 1426/1024.

      3. Try adding a new coupler variable.

       

      Expected result:

      A coupler variable should be added.

       

      Current result:

      A message is shown that the maximum is reached.

       

      The max size for input and output in profinet should be 1432. Inputs have 4 bytes predefined which leaves 1428 that should come from the coupler variables.

       

       

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  mminchev Martin Minchev
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: