Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.1100.4.5453, V1.0001.4.5448
    • Component/s: DTM
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      Schneider UNITY configuration tool is based on  FDT 1.21 XML schema.

      During a SetParameter call we get a XML with FDT 1.21 extensions <BusInformation busCategory="xyz" >. The validation of this XML fails because the DTM is using 1.2 XML schema files.

      Update the local XML schema files <FDTDataTypesSchema.xml> & <DTMParameterSchema.xml> to 1.21.

       

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  MKrifka Markus Krifka
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: