Details

    • Type: Bug
    • Status: Resolved
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.1100.7.7506
    • Fix Version/s: V1.1100.8.2322
    • Component/s: DTM
    • Labels:
      None
    • Account:
      SPC EtherCat Master (SPCETHERCATMA)

      Description

      If the SyncHskMode "device controlled" is set and the application is to be synchronized with the bus cycle by means of SYNC notification it does not succeed to activate this mode.

      The query of the SyncHskMode by means of xChannelCommonStatusBlock always returns bSyncHskMode == 0, and no SYNC events occur.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    FFaehrmann Frank Fährmann
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: