Uploaded image for project: 'EtherCAT Master DTM'
  1. EtherCAT Master DTM
  2. DTMV1ECM-303

Export of Master Configuration and Store/Load Fails

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.1000.4.6574, V1.1100.4.8584
    • Component/s: DTM
    • Labels:
      None
    • Account:
      SPC EtherCat Master (SPCETHERCATMA)

      Description

      See attached project in linked support issue. The project is corrupt but shows the devices to configure.

      Create a similar network and in device EL2252 V0.18 activate the process data of sync manager 3 (SysTime and Feedback).

      Click OK and try to export process data of the master -> it fails.

      Store the project and try to start the master -> it fails.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  MHofmann Martin Hofmann
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: