Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V0.0922.2.9762
    • Component/s: DTM
    • Labels:
      None
    • Account:
      SPC EtherCat Slave (SPCETHERCA)

      Description

      In some device description file, Fmmu and Sm are not matched.
      And an error is reported for this case:

      At least one SyncManager has no matched Fmmu, more Fmmu should be defined!

      This may not be an error.

      Hi Sven,

      As far as I understand, the following should be made:

      1. Do not show any error message for this case in slave DTM.
      2. Generate FPRD/FPWR commands for such Sm in Master DTM.

      Thank you!

      br,
      Jing

      --------------------------------------------------------------------------------

      Von: SBormann@hilscher.com
      Gesendet: Donnerstag, 12. November 2009 13:47
      An: JLi@hilscher.com; AJacob@hilscher.com
      Cc: DTsaava@hilscher.com
      Betreff: AW: Problems with EtherCat devices

      Hallo Andreas,

      @Jing: This is not required it is allowed to have Fmmus only for a part of the given Sync Managers.

      In fact, the master should fall back to use FPRD/FPWR commands in the case that a Sync Manager does not have a FMMU associated with it in the DDF.