Description
In some device description file, Fmmu and Sm are not matched.
And an error is reported for this case:
At least one SyncManager has no matched Fmmu, more Fmmu should be defined!
This may not be an error.
Hi Sven,
As far as I understand, the following should be made:
1. Do not show any error message for this case in slave DTM.
2. Generate FPRD/FPWR commands for such Sm in Master DTM.
Thank you!
br,
Jing
--------------------------------------------------------------------------------
Von: SBormann@hilscher.com
Gesendet: Donnerstag, 12. November 2009 13:47
An: JLi@hilscher.com; AJacob@hilscher.com
Cc: DTsaava@hilscher.com
Betreff: AW: Problems with EtherCat devices
Hallo Andreas,
@Jing: This is not required it is allowed to have Fmmus only for a part of the given Sync Managers.
In fact, the master should fall back to use FPRD/FPWR commands in the case that a Sync Manager does not have a FMMU associated with it in the DDF.