PB Stand Alone slave does not accept module "blank space" in the first slot

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.1000.4.2989, V1.1100.4.3818
    • Component/s: DTM
    • Labels:
      None
    • Account:
      SPC Profibus Slave (SPCPROFIBUSSL)

      Description

      In SYCON.net insert Profibus Stand Alone slave (CIFX DP/DPS) on the main line.
      In "Configuration -> Module" insert "blank space" as the first slot.
      Following errors are logged to the output window:

      Internal error! Function CreateModuleSignals(varIdentNumber, bstrSignaleID, bstrSignalNode) failed! -> Device: CIFX DP/DPS[CIFX DP/DPS]<2> 
      Internal error! Function m_pcDeviceInstance->InsertProcessChannelAttributes(...) failed! -> Device: CIFX DP/DPS[CIFX DP/DPS]<2> 
      Internal error! Function  GetModul(...) failed! -> Device: CIFX DP/DPS[CIFX DP/DPS]<2> 

      COMSOL\2016-08-1