Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: V1.1000.3.9612
-
Fix Version/s: V1.1000.4.2223
-
Component/s: DTM
-
Labels:None
-
Account:SPC Profibus Slave (SPCPROFIBUSSL)
Description
Test Description:
Check, if SYCON.net Configuration application can create, save and load projects.
Ressult
SYCON.net crashes, while trying to save a project with instanced PROFIBUS Slave DTM
Steps to reproduce:
1. Start SYCON.net.
2. Place CIFX DP/DPS Profibus Slave DTM (Stand-Alone) on the root line.
3. Save created project.