Details
-
Type: Change
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V2.1000.4.3063, V2.1100.4.3820
-
Fix Version/s: V2.1100.4.4879, V2.1000.4.4513, V2.0202.4.4783
-
Component/s: DTM
-
Labels:None
-
Account:SPC Profibus Master (SPCPROFIBUSMA)
Description
Remove "Event" indication from the Bus Diagnoses page.
Refer to the attached screenshot: "Bus Diag.png"
Background:
The issue is that netX firmware doesn't handle bErr_Event in GlobalSateField. This is why the PROFIBUS DTM gets incorrect value.
Decision has been made to remove the Event indication button from the DTM UI.
Help file needs to be updated accordingly.