Details
-
Type: Bug
-
Status: Resolved
-
Priority: Minor
-
Resolution: No Change Required
-
Affects Version/s: V2.1100.4.6093, V2.0301.4.6121
-
Fix Version/s: V2.0301.4.7878, V2.1100.4.8294
-
Component/s: DTM
-
Labels:None
-
Account:SPC Profibus Slave (SPCPROFIBUSSL)
Description
PB Generic Slave DTM reports incorrect Combi-IO modules total size for specific (custom made netX PROFIBUS ) descriptor file.
Participating sub-modules type and size are placed in Inputs and Outputs column, while 'In/Out' column value are 0.
The behavior described is not observed with attached Beckhof's descriptor.
Requirements :
SyconNET V1.400 Build 170505
Descriptors from attachments should be imported.
Steps to reproduce :
- Drop Generic Slave DTM on the master bus line
- Add Combi-IO module to slave configuration
- Verify Available and Configured modules details
Expected result :
"In\Out" column reports whole configured submodules data size (in bytes)
Actual result :
"In\Out" column reports 0, while submodules size are distributed between "Inputs" and "Outputs" columns