Bit-strobe mode: the "consumed size" reported to Master via DTM parameters should be 0.

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.0107.3.8667
    • Fix Version/s: V1.0107.4.7054, V1.1100.4.8272
    • Component/s: DTM
    • Labels:
      None
    • Account:
      SPC DeviceNet Slave (SPCDEVICESL)

      Description

      When configured in Bit-strobe mode the Generic Slave DTM should report consumed size 0.

      Expected result: Consumed size = 0.
      Current result: Consumed size = 8.