Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.0100.5.5704
    • Fix Version/s: V1.0100.5.6656, V1.0200.7.2151
    • Component/s: DTM
    • Labels:
      None
    • Account:
      SPC CC-Link IE FB Slave (SPCCCLINKISL)

      Description

      Test Description:

      Import a CSP+ file into the CSP+ creation support tool provided by CLPA. Visually check the description of indispensable items of the CSP+ file.

       

      Bug Description from Tester:

      Not expected Vendor Name is listed in NT 151-CCIES-RE device descriptor file. It is expected that Vendor Name in all sections (DeviceInfo, CommIFInfo, BlockInfo) is "Hilscher Gesellschaft fuer Systemautomation mbH" just like in the descriptor file for CIFX. Currently, the listed Vendor Name is: "Hilscher GmbH".

       

      Steps to reproduce:
      1. Open "0x0352_NT151-CCIES-RE(1100)_1_en.cspp" file via the Profile Creation Support Tool.
      2. Go to DEVICE / COMM_IF / BLOCK section.
      3. Check the Vendor Name listed in DEVICE_INFO / COMMIF_INFO / BLOCK_INFO.

       

      Expected result:
      Vendor Name = Hilscher Gesellschaft fuer Systemautomation mbH

       

      Actual result:
      Vendor Name = Hilscher GmbH

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  FFaehrmann Frank Fährmann
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: