Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.4.0.0
    • Fix Version/s: V3.4.0.9, V3.4.3.0
    • Labels:
      None
    • Account:
      SPC Profinet Master V3 operational (SPCPROFINETMA)

      Description

      The shortest Ethernet frames sent (e.g. DCP Identify Request for NameOfStation "d") are sent with too many padding bytes. It is expected that such a frame has a frame length of 64 byte (including FCS), current implementation will send frame with 68 byte (including FCS).

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: